Products
Spin-On Fuel Filters
- Phase Separation Detection & Water Sensing & Particulate Removing
- Phase Separation Detection "Alert" & Particulate Removing
- Water Sensing & Particulate Removing
- Particulate Removing Only
Other Product Categories

- Benefits
- Specifications
- Specifications Chart
- Dimensions/Flow Rate
- Note
Benefits
- PetroClear Adaptor Test Cap models TC 1-12 and TC 1.5-16-AD are designed to be installed on the adaptor base in place of a spin-on filter on a fuel dispenser. The Test Cap will allow service technicians to test and calibrate dispensers without the restriction or cost of a filter.
- PetroClear model TC 1-12 is designed to fit on a filter adaptor base with a 1"-12 UNF mounting thread (3/4" flow). Examples: Dresser Wayne, Bennett, Gasboy, etc.
- PetroClear model TC-1.5-16-AD is designed to fit on a filter adaptor base with 1.5"-16 UNF mounting thread (1" flow). Examples: Marconi (Gilbarco), Encore, Eclipse, Advantage and other high-flow dispensers.
- PetroClear Test Caps are not designed to be permanently installed in place of a filter. The product is not warranted against failure after prolonged use.
Specifications
- PetroClear Test Caps have a welded 1" Hex Nut on the dome end of the Test Cap to aid in both installation and removal.
- PetroClear Test Caps are designed for a maximum operating pressure of 100 psi.
- PetroClear model TC 1-12 and TC 1.5-16-AD are recognized by Underwriters Laboratories, Inc. for use on fuel dispensers.
- Test Cap model TC-1-12 and TC 1.5-16-AD utilize an epoxy-coated shell to eliminate oxidation which can cause pinhole leaks from the inside.
Specifications
| Model | ADAPTOR TC 1-12 | ADAPTOR TC 1.5-16-AD |
| Filter Type | Spin-On | Spin-On |
| Diameter | 3.68" | 3.74" |
| Flow | 3/4" flow | 1" flow |
| Gasket Material | Buna N | Buna N |
| Burst (Min.) | 250 psi (17.2 bar) | 250 psi (17.2 bar) |
Dimensions/Flow Rate
Note
NOTE: If you experience frequent filter changes, it is recommended that you have fuel samples analyzed to determine the source of contamination, such as water, dirt, rust, bacteria, phase separation, etc.